Eaton Blade UPS

The Eaton BladeUPS is a three-phase, scalable and modular UPS for high density computing environments, including virtualized or machine learning IT applications. The BladeUPS delivers  12 kW of efficient, reliable power in only 6U of rack space, including batteries. You can expand its capacity by combining 12 kW modules in a scalable, building block fashion to deliver 60 kW (N+1) from a single rack enclosure. This powerful configuration delivers higher power density than competitive, modular solutions while dissipating only one-third of the heat. By incorporating a BladeUPSs bus bar, you can easily self-install new paralleled units to keep up with your data center needs. While you can design a BladeUPS from scratch, you can also quickly deploy the Eaton BladeUPS Preassembled System, which is a turnkey solution featuring easy customization, shipping and installation. The BladeUPS can be easily monitored via the units’ brightly backlit LCD screen and through Eaton’s Intelligence Platform.

Product snapshot  
POWER RATING5-60 kW 
VOLTAGE208 and 400 Vac models
FREQUENCY

50/60 Hz

 
TOPOLOGYDouble conversion on demand
EFFICIENCYUp to 98% 
CONFIGURATIONRackmount 
   
Input characteristics 
INPUT VOLTAGE208 and 400 Vac models
VOLTAGE RANGE208V models: 180 to 265 Vac

400V models: 311 to 500 Vac
FREQUENCY RANGE50 or 60 Hz, ±5 Hz 
INPUT CURRENCY DISTORTION<5% with IT loads

(PFC power supplies)
INPUT POWER FACTOR>0.99 with IT loads

(PFC power supplies)
INRUSH CURRENTLoad dependent in high efficiency (HE) mode;

100% in normal mode
INPUT REQUIREMENTSThree-phase, four-wire + ground
BYPASS SOURCESame as input

(Single feed)
GENERATOR COMPATIBILITYFast sync slew rate for generator synchronization, programmable return to AC source delay
   
Output characteristics 
RATED OUTPUT VOLTAGE208V models: 180 to 225 Vac, Ph to Ph

400V models: 180 to 240 Vac, Ph to N
OUTPUT CONFIGURATIONThree-phase, four-wire + ground
OUTPUT FREQUENCY (NOMINAL)50 to 60 Hz auto-detection on startup
FREQUENCY REGULATION0.1 Hz free running 
LOAD POWER FACTOR RANGELagging: 0.7

Leading: 0.9
TOTAL OUTPUT VOLTAGE DISTORTION<3% with IT loads (PFC power supplies)

<5% non-linear or non-PFC power supplies
   
Batteries  
BATTERY TYPEVRLA-AGM 
BATTERY STRING VOLTAGE240 Vdc 
BATTERY TESTAutomatic battery test standard

Remote scheduling capable

Manual battery test from front display
BATTERY RECHARGE PROFILEABM three-stage charging technology
BATTERY CUT-OFF VOLTAGEAnnounced with alarm
EXTENDED BATTERIESUp to four 3U battery enclosures
   
Battery runtimes  
 50% LOADING100% LOADING
INTERNAL RUNTIME8 kW: 23 minutes

12 kW: 13 minutes
8 kW: 9 minutes

12 kW: 4.7 minutes
EXTENDED BATTERY CAPABILITY8 kW: 120 minutes

12 kW: 76 minutes
8 kW: 55 minutes

12 kW: 34 minutes
   
Dimensions  
 HEIGHTWIDTH
UPS10.3 in/267 mm

(6U)
17.4 in/442 mm
EBM5.2 in/132 mm

(3U)
17.2 in/437 mm
   
Weight  

CHASSIS WEIGHT WITHOUT BATTERIES OR ELECTRONICS

80 lb/36 kg 
CHASSIS WEIGHT WITH BATTERIES AND ELECTRONICS307 lb/140 kg 
UPS WEIGHT WITHOUT BATTERIES135 lb/61 kg 
UPS WEIGHT WITH 2 STRINGS OF BATTERIES307 lb/140 kg 
UPS WEIGHT WITH 1 STING OF BATTERIES218 lb/99 kg

(5 kW UPS only)
EBM SHIPPING WEIGHT170 lb/77 kg 
   
General characteristics 
HEAT DISSIPATION (HE MODEL)371 watts/1266 BTU/hr at 100% rated load (12 kW)

264 watts/903 BTU/hr at 100% rated load (8 kW)

210 watts/707 BTU/hr at 100% rated load (5 kW)
COOLINGFan cooled, temperature microcomprocessor monitored

Front air entry, rear exhaust
AUDIBLE NOISE, NORMAL OPERATION<60 dBA at 1 meter 
ALTITUDE BEFORE DERATING1000 meters (3300 ft ASL)
   
Communications and user interface 
SOFTWARE COMPATIBILITYUPS ships with IPM and IPP software
X-SLOT BAYSTwo 
CONTROL PANEL LCDTwo lines by 20 characters

Four menu-driven interface buttons

Four status-at-a-glance LEDs
MULTI-LANGUAGEEnglish standard

20 languages available
CONFIGURATION CHANGESUser capable, firmware auto configures
DRY CONTACT INPUTSTwo, user-configurable
DRY CONTACT OUTPUTSOne, user-configurable
   
Service  
INSTALLATIONUser capable,

optional factory serivce available
PREVENTIVE MAINTENANCEUser capable,

optional factory serivce available
CORRECTIVE MAINTENANCEUser capable,

optional factory serivce available
SERVICEABILITYHot-swappable batteries

Hot-swappable electronics modules

Automated internal maintenance bypass

Auto-configure firmware

Flash firmware upgradeable
   
Certifications  
SAFETY208V models: UL1778, cUL

400V models: CE, EN 62040-1, EN 60950-1: 2006, cULus
EMI/EMC208V models: FCC Part 15 Class A

EN 62040-2: 2006
SURGE PROTECTION208V ANSI C62.41, Cat B-3 EN 62000-4-5

ADDITIONAL RATINGS

EN 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8

HAZARDOUS MATERIALS (ROHS)

EU Directive 2002/95/EC
   

It’s time to think about our planet, go green

Libero gravida odio iaculis eros egestas primis semper sociosqu praesent elit ante