The Eaton 93E: simply effective

The Eaton 93E UPS delivers simply effective power protection for ever-expanding loads in today’s spaceconstrained data centres. Facilitating a lower total cost of ownership (TCO) through a combination of energyefficiency, high reliability and a compact footprint the 93E is an ideal solution for small – to medium – sized data centres and other applications desiring highly reliable power protection.

Eaton 93E UPS Technical Specifications

 
Power  
Ratings15kVA/13.5kW20kVA/18kW
30kVA/27kW40kVA/36kW
60kVA/54kW80kVA/72kW
100kVA/90kW120kVA/108kW
160kVA/144kW200kVA/180kW
TopologyDouble-conversion online UPS
Operating frequency50/60 Hz (40 to 72 Hz)
Input power factor>0.99 typical
Input current distortion5% THD 
Electrical input 
Nominal input voltage400/230V, 4 wire (380/415V selectable)
Input voltage range -15%, +20% from nominal (400V) at 100% load without depleting battery
Electrical output 
Nominal output voltage400/230, 4 wire (380/415V selectable)
Output voltage regulation ±1% Static; <5% dynamic at 100% resistive load change, <20 ms response time
Battery  
Battery192 to 240 Cells (Continual selectable for 15-80kVA) 216/222/228/234/240 Cells (Selectable for 100-200kVA)
Charging methodABM Cyclic Charging
General  
Efficiency >98% High-efficiency mode (15-80kVA)
>98.5% High-efficiency mode (100-200kVA)
>94% Double conversion mode (15-200kVA)
Overload150% for 1 minute, 125% for 10 minutes, >150% for 150ms
UPS bypassAutomatic on overload or UPS failure
Parallel technologyPowerware Hot Sync® Technology
Dimensions W x D x H (mm)500 x 710 x 960
500 x 710 x 1230
500 x 710 x 1500
600 x 800 x 1876
15-20kVA (with internal battery)
30kVA (with internal battery)
40kVA (with internal battery)
60-200kVA
Cabinet ratingIP20 with standard washable dust filters
Weights without internal battery72kg
120kg
202kg
245kg
283kg
311kg
457kg
15/20kVA
40kVA
60kVA
80kVA
100kVA
120kVA
160/200kVA
Weights with internal battery272kg
376kg
490kg
15/20kVA
30kVA
40kVA
Communications 
DisplayGraphical LCD with blue backlight
LEDs(4) LEDs for notice and alarm
Audible alarmsYes 
Communication ports(1) RS-232, (1) USB, (1) EPO
Communication slots(2) Mini-slot communication bays
Environmental 
Operating temperature0ºC to +40ºC
Batteries recommended max. +25ºC
Storage temperature -25ºC to +55ºC without batteries
+15ºC to +25ºC with batteries
Relative humidity5-95%, non-condensing
Audible noise15-20kVA≤55 dBA at 1m typical
30-40kVA≤62 dBA at 1m typical
60-120kVA≤65 dBA at 1m typical
160-200kVA≤70 dBA at 1m typical
Altitude<1000m at +40°C
Certifications 
EMI standardsEN55022/EN55024
EMC complianceIEC 62040-2
QualityISO 9001: 2000 and ISO 14001:1996
Communication accessories
Network-MSWeb/SNMP Card
Modbus-MSWeb/SNMP and Modbus Card
Relay-MSRelay (Dry Contact) Card -DB9 Connection
Industrial RelayRelay (Dry Contact) Card -Terminal Connection
116750224-001Environmental Monitor Probe (EMP) kit (need to plug
into Web/SNMP Card or Web/SNMP and Modbus
Card to work
System accessories 
Battery cabinets & battery circuit breakers (60-200kVA)
Maintenance Bypass Switches (MBS) (100-200kVA, standard on 15-80kVA)
Top cable entry (60-200kVA)
System parallel modules (60-200kVA)
Dual input kit (15-80kVA)
IP21 hood (15-200kVA)
Rear chimney (60-200kVA)
Due to continuous product improvements, specifications are subject to change without notice.